OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 12/07/2022 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
| OD AMB |
|
| 85 |
|
| 95 |
|
| 105 |
|
| 115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 875 | 0.98 | 0.99 |
| 1125 | 1.02 | 1.01 |
ARI RATING FOR COOLING
| CFM | CAPACITY (A) TEST | SEER | EER |
| 900 | 28000 | 14.00 | 11.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 12/07/2022 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
| TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
| OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
| 2 | 13.50 | 13.20 | 13.10 | 13.00 | 1.97 | 2.07 | 2.11 | 2.16 |
| 7 | 15.20 | 14.90 | 14.70 | 14.60 | 2.00 | 2.09 | 2.14 | 2.19 |
| 12 | 16.80 | 16.50 | 16.40 | 16.20 | 2.02 | 2.12 | 2.17 | 2.22 |
| 17 | 18.50 | 18.20 | 18.00 | 17.80 | 2.05 | 2.15 | 2.19 | 2.24 |
| 22 | 19.50 | 19.20 | 19.00 | 18.80 | 2.06 | 2.16 | 2.21 | 2.26 |
| 27 | 20.50 | 20.10 | 19.90 | 19.80 | 2.07 | 2.17 | 2.22 | 2.27 |
| 32 | 21.50 | 21.10 | 20.90 | 20.70 | 2.08 | 2.19 | 2.24 | 2.29 |
| 37 | 23.20 | 22.80 | 22.50 | 22.30 | 2.11 | 2.21 | 2.26 | 2.31 |
| 42 | 25.90 | 25.40 | 25.20 | 24.90 | 2.15 | 2.26 | 2.31 | 2.36 |
| 47 | 28.60 | 28.10 | 27.80 | 27.50 | 2.19 | 2.30 | 2.36 | 2.41 |
| 52 | 30.30 | 29.70 | 29.40 | 29.20 | 2.22 | 2.33 | 2.38 | 2.44 |
| 57 | 32.00 | 31.40 | 31.10 | 30.80 | 2.24 | 2.35 | 2.41 | 2.46 |
| 62 | 33.70 | 33.00 | 32.70 | 32.40 | 2.27 | 2.38 | 2.44 | 2.49 |
| 67 | 35.30 | 34.70 | 34.30 | 34.00 | 2.29 | 2.41 | 2.46 | 2.52 |
| 72 | 37.00 | 36.30 | 36.00 | 35.60 | 2.32 | 2.43 | 2.49 | 2.55 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 875 | 0.99 | 0.98 |
| 1125 | 1.01 | 1.03 |
ARI RATING FOR HEATING
| CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
| 900 | 27800 | 3.60 | 18000 | 2.50 | 8.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |