OD MODEL
4TWR4030G1

ID MODEL
TEM4A0B30S31+TDR

NOM CFM
1000

ARI REF #
8908428

Published Date: 12/07/2022

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
85
5926.7023.9026.426.7026.702.03
6328.0019.2022.525.6027.802.05
6729.9014.6017.921.1023.202.07
7132.5010.3013.516.7018.902.09
95
5925.5023.4025.525.5025.502.36
6326.7018.7021.925.1026.702.38
6728.6014.2017.420.6022.802.40
7131.009.7013.016.2018.302.43
105
5924.3022.9024.324.3024.302.69
6325.4018.2021.424.6025.402.71
6727.2013.6016.920.1022.202.74
7129.509.2012.515.7017.802.76
115
5923.0022.3023.023.0023.003.02
6324.1017.6020.924.1024.103.04
6725.8013.1016.419.6021.703.07
7128.008.7012.015.2017.303.10

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
8750.980.99
11251.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
9002800014.0011.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

 

OD MODEL
4TWR4030G1

ID MODEL
TEM4A0B30S31+TDR

NOM CFM
1000

ARI REF #
8908428

Published Date: 12/07/2022

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
213.5013.2013.1013.001.972.072.112.16
715.2014.9014.7014.602.002.092.142.19
1216.8016.5016.4016.202.022.122.172.22
1718.5018.2018.0017.802.052.152.192.24
2219.5019.2019.0018.802.062.162.212.26
2720.5020.1019.9019.802.072.172.222.27
3221.5021.1020.9020.702.082.192.242.29
3723.2022.8022.5022.302.112.212.262.31
4225.9025.4025.2024.902.152.262.312.36
4728.6028.1027.8027.502.192.302.362.41
5230.3029.7029.4029.202.222.332.382.44
5732.0031.4031.1030.802.242.352.412.46
6233.7033.0032.7032.402.272.382.442.49
6735.3034.7034.3034.002.292.412.462.52
7237.0036.3036.0035.602.322.432.492.55

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
8750.990.98
11251.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
900278003.60180002.508.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.