OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 05/08/2025 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
< font size="3"> OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM.< /font> | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1325 | 0.98 | 0.99 |
1700 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER2 | EER2 |
1335 | 46000 | 15.00 | 12.00 |
A.R.I. Standard Capacity Rating Conditions |
< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |