OD MODEL
4TTR6048J1

ID MODEL
TEM4B0C60S51+TDR

NOM CFM
1600

ARI REF #
210854874

Published Date: 05/08/2025

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

< font size="3"> OD AMB
ID WBTOT CAP72757880KW
85
5945.2035.9040.244.4045.203.16
6347.4029.5033.838.0040.903.19
6750.7023.4027.731.9034.803.22
7155.0017.5021.826.1028.903.25
95
5941.8034.4038.741.8041.803.72
6343.8028.0032.336.5039.403.75
6746.8021.9026.230.5033.303.79
7150.8016.1020.424.6027.503.82
105
5938.4032.9037.138.4038.404.27
6340.2026.6030.935.1037.904.32
6743.0020.5024.829.1031.904.36
7146.6014.7019.023.2026.104.40
115
5934.9031.4034.634.9034.904.83
6336.6025.1029.433.7036.504.88
6739.1019.1023.427.7030.504.93
7142.5013.3017.621.9024.704.98

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.< /font>CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
14000.980.99
18001.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEER2EER2
14554600015.2012.00

A.R.I. Standard Capacity Rating Conditions

< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.