OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 10/09/2025 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
| < font size="3"> OD AMB |
|
| 85 |
|
| 95 |
|
| 105 |
|
| 115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM.< /font> | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 1250 | 0.98 | 0.99 |
| 1600 | 1.02 | 1.01 |
ARI RATING FOR COOLING
| CFM | CAPACITY (A) TEST | SEER2 | EER2 |
| 1270 | 45000 | 15.20 | 12.00 |
A.R.I. Standard Capacity Rating Conditions |
< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |