OD MODEL
4TWX8036C1

ID MODEL
4TXCD008DS3

FURNACE
S9V2B080U4PSB

NOM CFM
1200

ARI REF #
201801791

Published Date: 12/07/2022

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
85
5935.8030.6034.435.8035.802.52
6337.5024.8028.732.5035.102.55
6740.1019.4023.327.1029.702.57
7143.5014.1018.021.8024.402.59
95
5933.9029.7033.133.9033.902.84
6335.6024.1027.931.7034.302.87
6738.0018.6022.526.3028.902.90
7141.2013.3017.221.0023.602.92
105
5932.1028.9031.832.1032.103.16
6333.6023.2027.130.9033.503.19
6735.9017.8021.725.5028.103.22
7139.0012.6016.420.3022.803.26
115
5930.2028.1030.230.2030.203.48
6331.7022.5026.330.1031.703.52
6733.9017.1020.924.8027.303.55
7136.7011.8015.719.5022.003.59

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
10500.980.99
13501.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
11653780017.5013.00

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

 

OD MODEL
4TWX8036C1

ID MODEL
4TXCD008DS3

FURNACE
S9V2B080U4PSB

NOM CFM
1200

ARI REF #
201801791

Published Date: 12/07/2022

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
215.7015.4015.3015.102.172.282.342.39
717.8017.5017.3017.202.192.312.362.42
1219.9019.6019.4019.202.222.332.392.44
1722.1021.6021.4021.202.242.362.412.47
2223.3022.9022.7022.502.252.372.422.48
2724.6024.2023.9023.702.262.382.442.49
3225.9025.4025.2024.902.272.392.452.51
3728.0027.5027.2027.002.302.412.472.53
4231.4030.8030.5030.202.342.462.522.58
4734.7034.1033.7033.402.382.502.562.63
5236.8036.1035.8035.502.402.532.592.65
5738.9038.2037.8037.502.432.552.622.68
6241.1040.3039.9039.502.452.582.642.70
6743.2042.4042.0041.502.472.602.672.73
7245.3044.4044.0043.602.492.632.692.76

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
10500.990.98
13501.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
1165340004.00216002.708.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

LOW STAGE

OD MODEL
4TWX8036C1

ID MODEL
4TXCD008DS3

FURNACE
S9V2B080U4PSB

NOM CFM
1000

ARI REF #
201801791

Published Date: 12/07/2022

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
75
5927.4022.5025.227.4027.401.36
6328.7018.4021.223.9025.701.37
6730.6014.5017.320.0021.801.39
7133.2010.8013.516.3018.101.40
85
5926.1021.9024.726.1026.101.62
6327.4017.9020.623.4025.201.64
6729.2014.0016.719.5021.301.65
7131.7010.3013.015.7017.601.67
90
5925.5021.7024.425.5025.501.75
6326.7017.6020.323.1024.901.77
6728.5013.7016.519.2021.001.78
7131.0010.0012.815.5017.301.80
95
5924.8021.4024.024.8024.801.88
6326.0017.3020.122.8024.601.90
6727.8013.5016.218.9020.801.91
7130.209.8012.515.2017.001.93

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
8750.980.99
11251.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
11652771717.5013.00

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

LOW STAGE

 

 

OD MODEL
4TWX8036C1

ID MODEL
4TXCD008DS3

FURNACE
S9V2B080U4PSB

NOM CFM
1000

ARI REF #
201801791

Published Date: 12/07/2022

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
2216.2015.9015.7015.601.781.871.921.96
2717.4017.0016.9016.701.771.861.911.96
3218.6018.2018.0017.901.761.861.901.95
3720.4020.0019.8019.601.771.861.911.95
4223.0022.6022.4022.201.791.881.931.97
4725.7025.2025.0024.801.811.901.952.00
5227.5027.0026.7026.501.811.901.952.00
5729.3028.7028.5028.201.811.911.962.00
6231.1030.5030.2029.901.821.911.962.01
6732.9032.3032.0031.601.821.921.962.01
7234.7034.0033.7033.401.821.921.972.02

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
8750.990.98
11251.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
1165340004.00216002.708.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.