OD MODEL |
ID MODEL |
NOM CFM |
ARI REF # |
|
Document Date: 2/6/2008 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
| OD AMB |
|
| 85 |
|
| 95 |
|
| 105 |
|
| 115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 1050 | 0.97 | 0.98 |
| 1350 | 1.03 | 1.02 |
ARI RATING FOR COOLING
| CFM | CAPACITY (A) TEST | SEER | EER |
| 1050 | 34400 | 13.00 | 11.00 |
|
A.R.I. Standard Capacity Rating Conditions |
|
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL |
ID MODEL |
NOM CFM |
ARI REF # |
|
Document Date: 2/6/2008 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
| TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
| OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
| 2 | 15.0 | 14.7 | 14.5 | 14.4 | 2.3 | 2.5 | 2.6 | 2.6 |
| 7 | 16.9 | 16.6 | 16.5 | 16.3 | 2.4 | 2.5 | 2.6 | 2.7 |
| 12 | 18.9 | 18.6 | 18.4 | 18.2 | 2.4 | 2.6 | 2.6 | 2.7 |
| 17 | 20.9 | 20.5 | 20.3 | 20.1 | 2.5 | 2.6 | 2.7 | 2.8 |
| 22 | 21.8 | 21.4 | 21.2 | 21.0 | 2.5 | 2.6 | 2.7 | 2.8 |
| 27 | 22.8 | 22.3 | 22.1 | 21.9 | 2.5 | 2.6 | 2.7 | 2.8 |
| 32 | 23.7 | 23.2 | 23.0 | 22.8 | 2.5 | 2.7 | 2.7 | 2.8 |
| 37 | 25.7 | 25.2 | 24.9 | 24.7 | 2.5 | 2.7 | 2.8 | 2.9 |
| 42 | 29.2 | 28.7 | 28.4 | 28.2 | 2.6 | 2.8 | 2.9 | 3.0 |
| 47 | 32.8 | 32.2 | 31.9 | 31.6 | 2.7 | 2.9 | 2.9 | 3.0 |
| 52 | 34.8 | 34.2 | 33.8 | 33.5 | 2.7 | 2.9 | 3.0 | 3.1 |
| 57 | 36.8 | 36.1 | 35.7 | 35.4 | 2.8 | 3.0 | 3.0 | 3.1 |
| 62 | 38.8 | 38.1 | 37.7 | 37.3 | 2.8 | 3.0 | 3.1 | 3.2 |
| 67 | 40.8 | 40.0 | 39.6 | 39.2 | 2.9 | 3.0 | 3.1 | 3.2 |
| 72 | 42.8 | 42.0 | 41.5 | 41.2 | 2.9 | 3.1 | 3.2 | 3.3 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 1050 | 0.987 | 0.975 |
| 1350 | 1.011 | 1.025 |
ARI RATING FOR HEATING
| CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
| 1050 | 31400 | 3.28 | 20000 | 2.30 | 8.20 |
|
A.R.I. Standard Capacity Rating Conditions |
|
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |