OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 12/07/2022 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
525 | 0.98 | 0.99 |
675 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER | EER |
550 | 18800 | 16.00 | 12.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 12/07/2022 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 6.80 | 6.70 | 6.60 | 6.50 | 1.15 | 1.21 | 1.24 | 1.27 |
7 | 7.90 | 7.80 | 7.70 | 7.60 | 1.16 | 1.22 | 1.25 | 1.28 |
12 | 9.10 | 8.90 | 8.90 | 8.80 | 1.17 | 1.23 | 1.26 | 1.29 |
17 | 10.30 | 10.10 | 10.00 | 9.90 | 1.18 | 1.24 | 1.27 | 1.30 |
22 | 11.00 | 10.80 | 10.70 | 10.60 | 1.18 | 1.24 | 1.27 | 1.30 |
27 | 11.80 | 11.60 | 11.50 | 11.40 | 1.18 | 1.25 | 1.28 | 1.31 |
32 | 12.60 | 12.30 | 12.20 | 12.10 | 1.19 | 1.25 | 1.28 | 1.31 |
37 | 13.70 | 13.50 | 13.30 | 13.20 | 1.20 | 1.26 | 1.29 | 1.32 |
42 | 15.50 | 15.20 | 15.10 | 14.90 | 1.22 | 1.28 | 1.31 | 1.34 |
47 | 17.30 | 16.90 | 16.80 | 16.60 | 1.24 | 1.30 | 1.33 | 1.37 |
52 | 18.40 | 18.10 | 17.90 | 17.70 | 1.25 | 1.31 | 1.34 | 1.38 |
57 | 19.60 | 19.20 | 19.00 | 18.90 | 1.26 | 1.32 | 1.36 | 1.39 |
62 | 20.70 | 20.40 | 20.20 | 20.00 | 1.27 | 1.33 | 1.37 | 1.40 |
67 | 21.90 | 21.50 | 21.30 | 21.10 | 1.27 | 1.34 | 1.38 | 1.41 |
72 | 23.10 | 22.60 | 22.40 | 22.20 | 1.28 | 1.35 | 1.39 | 1.42 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
525 | 0.99 | 0.98 |
675 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
550 | 16800 | 3.84 | 10000 | 2.40 | 9.00 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |