OD MODEL
4TWR4042G1

ID MODEL
GAM5B0C42M31

NOM CFM
1260

ARI REF #
8932641

Published Date: 12/07/2022

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
85
5939.2031.9035.839.2039.002.90
6341.1026.2030.133.8036.402.93
6743.9020.8024.628.4030.902.96
7147.6015.6019.423.2025.702.98
95
5937.5031.1035.037.5037.503.30
6339.3025.5029.333.1035.603.33
6742.0020.1023.927.7030.203.36
7145.5014.9018.722.5025.003.39
105
5935.7030.3034.235.7035.703.69
6337.5024.7028.632.3034.803.73
6740.0019.3023.226.9029.403.77
7143.4014.1018.021.7024.303.80
115
5934.0029.6033.134.0034.004.09
6335.7024.0027.831.6034.104.13
6738.1018.6022.426.2028.704.17
7141.4013.4017.321.0023.604.21

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
11000.980.99
14251.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
11154100014.5012.00

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

 

OD MODEL
4TWR4042G1

ID MODEL
GAM5B0C42M31

NOM CFM
1400

ARI REF #
8932641

Published Date: 12/07/2022

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
218.9018.5018.4018.202.582.722.782.85
721.0020.6020.4020.202.622.762.832.90
1223.1022.7022.5022.302.662.802.872.94
1725.2024.8024.5024.302.702.842.912.98
2226.5026.0025.7025.502.722.872.943.01
2727.7027.1026.9026.602.742.892.963.03
3228.9028.3028.1027.802.772.912.993.06
3731.0030.4030.1029.802.812.953.033.10
4234.5033.8033.5033.202.873.023.103.17
4738.0037.3036.9036.602.933.093.173.25
5240.1039.3039.0038.602.973.133.213.29
5742.2041.4041.0040.603.013.173.253.33
6244.3043.5043.1042.703.053.213.293.38
6746.5045.6045.2044.703.093.253.343.42
7248.6047.7047.2046.803.133.303.383.46

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
12250.990.98
15751.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
1115364003.60242002.608.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.