OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 11/04/2018 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1400 | 0.98 | 0.99 |
1800 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER | EER |
1430 | 48000 | 15.00 | 12.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 11/04/2018 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 22.80 | 22.30 | 22.10 | 21.90 | 2.95 | 3.11 | 3.19 | 3.27 |
7 | 25.60 | 25.10 | 24.90 | 24.70 | 3.00 | 3.16 | 3.23 | 3.31 |
12 | 28.50 | 27.90 | 27.70 | 27.40 | 3.04 | 3.20 | 3.28 | 3.36 |
17 | 31.30 | 30.70 | 30.40 | 30.10 | 3.08 | 3.24 | 3.33 | 3.41 |
22 | 33.00 | 32.40 | 32.10 | 31.80 | 3.11 | 3.27 | 3.35 | 3.44 |
27 | 34.70 | 34.00 | 33.70 | 33.40 | 3.13 | 3.30 | 3.38 | 3.46 |
32 | 36.40 | 35.70 | 35.40 | 35.00 | 3.16 | 3.32 | 3.41 | 3.49 |
37 | 39.20 | 38.50 | 38.10 | 37.80 | 3.20 | 3.37 | 3.45 | 3.54 |
42 | 43.80 | 43.00 | 42.60 | 42.20 | 3.27 | 3.44 | 3.53 | 3.62 |
47 | 48.40 | 47.50 | 47.00 | 46.60 | 3.33 | 3.51 | 3.60 | 3.69 |
52 | 51.30 | 50.30 | 49.80 | 49.30 | 3.37 | 3.56 | 3.65 | 3.74 |
57 | 54.10 | 53.10 | 52.60 | 52.10 | 3.42 | 3.60 | 3.69 | 3.79 |
62 | 57.00 | 55.90 | 55.40 | 54.80 | 3.46 | 3.65 | 3.74 | 3.83 |
67 | 59.80 | 58.70 | 58.10 | 57.60 | 3.50 | 3.69 | 3.79 | 3.88 |
72 | 62.70 | 61.50 | 60.90 | 60.30 | 3.54 | 3.74 | 3.83 | 3.93 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1400 | 0.99 | 0.98 |
1800 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
1430 | 47000 | 4.00 | 30400 | 2.80 | 9.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |