OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1005 | 0.98 | 0.99 |
1295 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER | EER |
1150 | 35000 | 14.00 | 12.00 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 15.21 | 14.79 | 14.93 | 14.65 | 2.18 | 2.28 | 2.32 | 2.37 |
7 | 16.93 | 16.46 | 16.62 | 16.3 | 2.24 | 2.33 | 2.38 | 2.43 |
12 | 18.68 | 18.16 | 18.34 | 17.99 | 2.29 | 2.39 | 2.44 | 2.49 |
17 | 20.48 | 20.1 | 19.91 | 19.72 | 2.35 | 2.45 | 2.5 | 2.55 |
22 | 22.37 | 21.94 | 21.73 | 21.52 | 2.39 | 2.49 | 2.55 | 2.6 |
27 | 24.25 | 23.78 | 23.55 | 23.31 | 2.43 | 2.54 | 2.59 | 2.65 |
32 | 25.79 | 25.27 | 25.01 | 24.76 | 2.47 | 2.58 | 2.64 | 2.7 |
37 | 28.38 | 27.82 | 27.54 | 27.26 | 2.54 | 2.66 | 2.71 | 2.77 |
42 | 32.04 | 31.43 | 31.13 | 30.83 | 2.61 | 2.73 | 2.79 | 2.85 |
47 | 35.0 | 35.0 | 35.0 | 34.75 | 2.67 | 2.8 | 2.86 | 2.93 |
52 | 35.0 | 35.0 | 35.0 | 35.0 | 2.73 | 2.86 | 2.92 | 2.99 |
57 | 35.0 | 35.0 | 35.0 | 35.0 | 2.78 | 2.92 | 2.98 | 3.05 |
62 | 35.0 | 35.0 | 35.0 | 35.0 | 2.84 | 2.98 | 3.04 | 3.11 |
67 | 35.0 | 35.0 | 35.0 | 35.0 | 2.89 | 3.03 | 3.1 | 3.17 |
72 | 35.0 | 35.0 | 35.0 | 35.0 | 2.95 | 3.09 | 3.16 | 3.24 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1005 | 0.99 | 0.98 |
1295 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
1005 | 35000 | 3.7 | 20000 | 2.4 | 8.2 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |