OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1375 | 0.98 | 0.99 |
1750 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER | EER |
1380 | 48000 | 15.00 | 12.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 23.50 | 23.10 | 22.90 | 22.60 | 3.53 | 3.72 | 3.81 | 3.90 |
7 | 26.40 | 25.90 | 25.60 | 25.40 | 3.53 | 3.72 | 3.81 | 3.91 |
12 | 29.20 | 28.70 | 28.40 | 28.10 | 3.54 | 3.73 | 3.82 | 3.91 |
17 | 32.10 | 31.50 | 31.20 | 30.80 | 3.54 | 3.73 | 3.82 | 3.92 |
22 | 33.70 | 33.10 | 32.80 | 32.50 | 3.53 | 3.72 | 3.81 | 3.90 |
27 | 35.40 | 34.70 | 34.40 | 34.10 | 3.51 | 3.70 | 3.79 | 3.89 |
32 | 37.10 | 36.40 | 36.00 | 35.70 | 3.50 | 3.69 | 3.78 | 3.87 |
37 | 39.90 | 39.20 | 38.80 | 38.40 | 3.51 | 3.69 | 3.79 | 3.88 |
42 | 44.50 | 43.70 | 43.30 | 42.80 | 3.54 | 3.73 | 3.82 | 3.91 |
47 | 49.10 | 48.20 | 47.70 | 47.30 | 3.57 | 3.76 | 3.86 | 3.95 |
52 | 52.00 | 51.00 | 50.50 | 50.00 | 3.57 | 3.77 | 3.86 | 3.96 |
57 | 54.80 | 53.80 | 53.30 | 52.70 | 3.58 | 3.77 | 3.87 | 3.96 |
62 | 57.60 | 56.60 | 56.00 | 55.50 | 3.58 | 3.78 | 3.87 | 3.97 |
67 | 60.50 | 59.30 | 58.80 | 58.20 | 3.59 | 3.78 | 3.88 | 3.97 |
72 | 63.30 | 62.10 | 61.50 | 61.00 | 3.59 | 3.79 | 3.88 | 3.98 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1400 | 0.99 | 0.98 |
1800 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
1380 | 47500 | 3.80 | 31000 | 2.50 | 8.55 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |