OD MODEL
4TWX5049E1

ID MODEL
4TXCD010DS3

FURNACE
S9V2C100U5PSB

NOM CFM
1600

ARI REF #
202284204(D)

Published Date: 06/05/2019

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
85
5947.1038.5043.347.1047.103.45
6349.4031.5036.340.9044.003.48
6752.8024.9029.634.2037.403.51
7157.3018.4023.227.8031.003.54
95
5943.3036.8041.643.3043.303.74
6345.4029.9034.639.3042.403.78
6748.5023.2028.032.6035.703.81
7152.7016.8021.626.2029.403.85
105
5939.6035.2039.039.6039.604.03
6341.5028.3033.037.7040.804.07
6744.3021.7026.431.0034.204.11
7148.1015.3020.024.7027.804.15
115
5935.8033.5035.835.8035.804.32
6337.5026.7031.436.1037.504.37
6740.1020.1024.929.5032.604.41
7143.5013.7018.523.1026.204.45

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
14000.980.99
18001.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
15054800015.0012.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

 

OD MODEL
4TWX5049E1

ID MODEL
4TXCD010DS3

FURNACE
S9V2C100U5PSB

NOM CFM
1600

ARI REF #
202284204(D)

Published Date: 06/05/2019

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
223.6023.2023.0022.703.553.743.833.93
726.4025.9025.7025.403.543.723.823.91
1229.2028.6028.4028.103.523.713.803.89
1732.0031.4031.1030.803.513.693.793.88
2233.6033.0032.6032.303.483.663.753.84
2735.2034.5034.2033.903.443.623.713.80
3236.8036.1035.8035.403.413.593.683.77
3739.6038.9038.5038.103.403.573.663.75
4244.1043.3042.9042.503.413.593.683.77
4748.7047.8047.3046.803.433.613.703.78
5251.4050.5050.0049.503.413.593.683.77
5754.2053.2052.7052.203.403.583.663.75
6257.0055.9055.4054.903.383.563.653.74
6759.8058.7058.1057.603.373.553.633.72
7262.6061.4060.8060.203.363.533.623.71

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
14000.990.98
18001.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
1505475003.90312002.508.55

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.