OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1250 | 0.98 | 0.99 |
1625 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER | EER |
1280 | 48000 | 15.00 | 12.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 24.00 | 23.50 | 23.30 | 23.10 | 3.77 | 3.98 | 4.08 | 4.18 |
7 | 26.80 | 26.30 | 26.00 | 25.80 | 3.76 | 3.97 | 4.07 | 4.17 |
12 | 29.50 | 29.00 | 28.70 | 28.40 | 3.75 | 3.96 | 4.06 | 4.16 |
17 | 32.30 | 31.70 | 31.40 | 31.10 | 3.74 | 3.95 | 4.05 | 4.15 |
22 | 33.90 | 33.30 | 33.00 | 32.70 | 3.71 | 3.91 | 4.01 | 4.11 |
27 | 35.50 | 34.90 | 34.50 | 34.20 | 3.68 | 3.88 | 3.98 | 4.08 |
32 | 37.10 | 36.40 | 36.10 | 35.70 | 3.65 | 3.84 | 3.94 | 4.04 |
37 | 39.90 | 39.20 | 38.80 | 38.40 | 3.64 | 3.83 | 3.93 | 4.03 |
42 | 44.50 | 43.60 | 43.20 | 42.80 | 3.66 | 3.86 | 3.96 | 4.05 |
47 | 49.00 | 48.10 | 47.60 | 47.20 | 3.68 | 3.88 | 3.98 | 4.08 |
52 | 51.80 | 50.80 | 50.30 | 49.80 | 3.67 | 3.87 | 3.97 | 4.07 |
57 | 54.60 | 53.50 | 53.00 | 52.50 | 3.66 | 3.86 | 3.96 | 4.06 |
62 | 57.40 | 56.30 | 55.70 | 55.20 | 3.65 | 3.85 | 3.95 | 4.05 |
67 | 60.10 | 59.00 | 58.40 | 57.90 | 3.64 | 3.84 | 3.94 | 4.03 |
72 | 62.90 | 61.70 | 61.10 | 60.60 | 3.63 | 3.83 | 3.92 | 4.02 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1400 | 0.99 | 0.98 |
1800 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
1280 | 47000 | 3.70 | 31000 | 2.40 | 8.55 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |