OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
| OD AMB |
|
| 85 |
|
| 95 |
|
| 105 |
|
| 115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 1400 | 0.98 | 0.99 |
| 1800 | 1.02 | 1.01 |
ARI RATING FOR COOLING
| CFM | CAPACITY (A) TEST | SEER | EER |
| 1470 | 48000 | 15.00 | 12.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 06/05/2019 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
| TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
| OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
| 2 | 23.70 | 23.20 | 23.00 | 22.80 | 3.52 | 3.71 | 3.80 | 3.89 |
| 7 | 26.50 | 26.00 | 25.70 | 25.50 | 3.52 | 3.71 | 3.80 | 3.89 |
| 12 | 29.30 | 28.70 | 28.40 | 28.20 | 3.52 | 3.71 | 3.80 | 3.89 |
| 17 | 32.00 | 31.40 | 31.10 | 30.80 | 3.53 | 3.71 | 3.80 | 3.89 |
| 22 | 33.70 | 33.00 | 32.70 | 32.40 | 3.51 | 3.69 | 3.78 | 3.87 |
| 27 | 35.30 | 34.60 | 34.30 | 34.00 | 3.49 | 3.67 | 3.76 | 3.85 |
| 32 | 36.90 | 36.20 | 35.90 | 35.50 | 3.47 | 3.65 | 3.74 | 3.83 |
| 37 | 39.70 | 38.90 | 38.60 | 38.20 | 3.47 | 3.65 | 3.75 | 3.84 |
| 42 | 44.20 | 43.40 | 43.00 | 42.60 | 3.50 | 3.69 | 3.78 | 3.87 |
| 47 | 48.80 | 47.90 | 47.40 | 47.00 | 3.53 | 3.72 | 3.81 | 3.90 |
| 52 | 51.60 | 50.60 | 50.10 | 49.60 | 3.53 | 3.72 | 3.81 | 3.90 |
| 57 | 54.40 | 53.30 | 52.80 | 52.30 | 3.53 | 3.72 | 3.81 | 3.90 |
| 62 | 57.10 | 56.10 | 55.50 | 55.00 | 3.53 | 3.72 | 3.81 | 3.90 |
| 67 | 59.90 | 58.80 | 58.30 | 57.70 | 3.53 | 3.72 | 3.81 | 3.91 |
| 72 | 62.70 | 61.60 | 61.00 | 60.40 | 3.54 | 3.72 | 3.81 | 3.91 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
| AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
| 1400 | 0.99 | 0.98 |
| 1800 | 1.01 | 1.03 |
ARI RATING FOR HEATING
| CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
| 1470 | 47500 | 3.80 | 31200 | 2.50 | 8.55 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |